title: "Embassy Security Glass Installation London | Ballistic-Rated Case Study"
canonical_url: "https://gt.glass/case-studies/embassy-security-upgrade"
last_updated: "2026-09-24T03:20:39.826Z"
meta:
  author: "Glass Technique Ltd"
  description: "High-security glazing retrofit for a London embassy — Technopact FB7 ballistic-rated glass with forced-entry resistance across ground-floor fenestration."
  keywords: "glass supplier London, switchable glass, smart glass, security glass, fire-rated glass, acoustic glass, PDLC glass, mesh laminated glass, LED glass, Glass Technique Ltd"
  "og:description": "High-security glazing retrofit for a London embassy — Technopact FB7 ballistic-rated glass with forced-entry resistance across ground-floor fenestration."
  "og:title": "Embassy Security Upgrade — Ballistic-Rated Glazing"
  "twitter:description": "High-security glazing retrofit for a London embassy — Technopact FB7 ballistic-rated glass with forced-entry resistance across ground-floor fenestration."
  "twitter:title": "Embassy Security Upgrade — Ballistic-Rated Glazing"
---

Search products

[Back to Projects](https://gt.glass/projects)

Case Study

# Embassy Security Upgrade — Ballistic-Rated Glazing

Government / SecurityLondon, UKDuration: 4 monthsArea: Not disclosed

Glass Technique Ltd supplied and coordinated the installation of ballistic-rated security glazing for a diplomatic building in central London. The project replaced existing ground-floor windows with Technopact FB7 bullet-resistant glass systems with forced-entry resistance, meeting the highest security classification for occupied buildings.

![Security glass panel installation for embassy building](https://gt.glass/images/case-studies/embassy-security-upgrade/security-glass-install.jpg)

## The Challenge

A diplomatic building in central London required a security upgrade to all ground-floor fenestration. The existing glazing provided insufficient protection against forced entry and ballistic threats. The replacement system had to meet BS EN 1063 BR7 ballistic classification and BS EN 356 P8B forced-entry resistance while maintaining the building's architectural appearance. All work had to be completed without disrupting embassy operations or compromising the building's security perimeter during installation.

## Our Solution

Glass Technique Ltd specified and installed Technopact FB7 ballistic-rated glass systems across all ground-floor windows. Each panel was a multi-laminate composite of glass and polycarbonate interlayers, providing both ballistic and forced-entry protection. Installation was phased to maintain security coverage at all times — no more than two window openings were replaced simultaneously. All frames were certified steel systems with anti-lever protection, and the installation was completed under security-cleared supervision.

## Products Used

[Technopact Security Glass](https://gt.glass/product/security-glass)

## Technical Details

Ballistic RatingBR7 (BS EN 1063)

Forced-Entry RatingP8B (BS EN 356)

ConstructionMulti-laminate glass + polycarbonate composite

Frame SystemCertified steel with anti-lever protection

InstallationPhased, security-cleared, 4 months

## Results

The embassy achieved the highest security classification for occupied buildings. All ground-floor fenestration was replaced without disrupting embassy operations or compromising the security perimeter. The installation passed independent security audit on first inspection, and all certification documentation was provided for the building's security records.

Start Your Project

## Discuss your glass requirements

[Contact Us→](https://gt.glass/contact) [ Call +44 20 3838 0300](tel:+442038380300)